Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 234: 113705, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194837

RESUMO

Hollow-core microstructured optical waveguides (HC-MOW) have recently emerged in sensing technologies, including the gas and liquid detection for industrial as well as clinical applications. Antiresonant HC-MOW provide capabilities for applications in refractive index (RI) sensing, while the long optical path for analyte-light interaction in HC-MOW leads to increased sensitivity of sensor based on Raman scattering signal measurements. In this study, we developed a two-in-one sensor device using HC-MOW for RI and Raman scattering detection. The performance of the sensor was evaluated by characterizing protein-copolymer multicomponent colloids, specifically, bovine serum albumin (BSA) and poly(N - vinyl-2 -pyrrolidone-co-acrylic acid) P(VP-AA) nano-sized complexes and microbubbles of the corresponding shell. Monocomponent solutions showed linear dependencies of RI and characteristic Raman peak intensities on mass concentration. Multicomponent Raman sensing of BSA@P(VP-AA) complexes and microbubbles revealed that changes in P(VP-AA) characteristic peak intensities can describe interactions between components needed to produce colloid systems. RI sensing of multicomponent colloids demonstrated linear dependence on total mass concentrations for BSA@P(VP-AA) complexes, while corresponding BSA@P(VP-AA) microbubbles can be detected with concentrations as high as 4.0 × 108 MB/mL. Therefore, the developed two-in-one sensor of RI and Raman scattering can be used the robust characterization of albumin-based colloids designed for therapeutic and diagnostic needs.


Assuntos
Refratometria , Análise Espectral Raman , Coloides
2.
Anal Bioanal Chem ; 412(24): 6509-6517, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32388579

RESUMO

A new facile and fast approach to the synthesis of polyaniline (PANi) molecularly imprinted polymers (MIPs) based on aniline oxidative chemical polymerization was proposed for protein recognition. For the first time, a surface imprinting strategy was implemented for the synthesis of PANi MIPs on the inner surface of soft glass polycapillaries (PC) with a large (2237) number of individual microcapillaries. Two different PANi layers-(i) PANi film and (ii) protein imprinted PANi nanowires-were synthesized sequentially. Uniform and highly stable PANi film was synthesized by oxidative polymerization at pH< 1. The synthesis of PANi MIPs on the PANi film pre-coated surface improved the reproducibility of PANi MIP formation. PANi MIP nanowires were synthesized at "mild" conditions (pH > 4.5) to preserve the protein template activity. The binding of horseradish peroxidase (HRP) molecules on the PANi MIP selective sites was confirmed by photometry (TMB chromogenic reaction), SEM images, and FTIR spectroscopy. The developed PANi MIPs enable HRP determination with a limit of detection (LOD) as low as 1.00 and 0.07 ng mL-1 on the glass slips and PC, respectively. The PANi MIPs are characterized by high stability; they are reversible and selective to HRP. The proposed approach allows PANi MIPs to be obtained for proteins on different supports and to create new materials for separation and sensing. Graphical abstract.


Assuntos
Compostos de Anilina/química , Peroxidase do Rábano Silvestre/isolamento & purificação , Polímeros Molecularmente Impressos/química , Peroxidase do Rábano Silvestre/análise , Limite de Detecção , Impressão Molecular , Nanofios/química , Nanofios/ultraestrutura , Fotometria , Espectroscopia de Infravermelho com Transformada de Fourier
3.
Talanta ; 208: 120445, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31816708

RESUMO

Multi-channel capillaries (MC) formed from thousands individual microcapillaries with diameters ranging 10-100 µm are of a great interest for their use as platforms for molecular imprinting due to their relatively large surface area, high mechanical stability and possibility of facile integration in sensor systems. The manuscript proposes a new format of immunoassay based on imprinted protein immobilized on a MC inner surface modified with poly-l-lysine. The combination of the environmentally friendly, easy-to-produce and cheap recognition element with the carrier allowing to increase the assay sensitivity makes the described technique a perspective alternative for the existing screening tests. Two bioimprinting approaches were described. The imprinted protein (ovalbumin, OVA) primarily prepared separately and later immobilized on a MC structure was compared to the imprinted OVA directly prepared on the MC surface. Detection of a food contaminant zearalenone was chosen as a proof-of-concept. In a case of the immobilization of the primarily prepared imprinted OVA the reached limit of detection (LOD) was 0.8 ng/mL, and for the in-situ imprinted OVA the LOD was 0.12 ng/mL. The sensitivity of the developed bioimprinted assay was comparable to the commercially available ELISA kits for ZEN detection. The OVA in-situ imprinted on the MC surface was tested for the detection of ZEN in artificially spiked wheat samples. The high recovery values (88-112%) and good repeatability (RSD of 8.5-9.6%) were demonstrated allowing to conclude that the IPs-based MC-ELISA is a promising tool for analysis of the mycotoxin in complex matrices.


Assuntos
Contaminação de Alimentos/análise , Imunoensaio/métodos , Impressão Molecular , Ovalbumina/química , Triticum/química , Zearalenona/análise , Vidro , Peroxidase do Rábano Silvestre/química , Proteínas Imobilizadas/química , Polilisina/química , Soroalbumina Bovina/química , Zearalenona/química
4.
Anal Bioanal Chem ; 411(27): 7055-7059, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31598742

RESUMO

A new perspective on the relevant problem-creating simple, rapid, and efficient protein sensors based on microstructured optical fibers using a simple homogeneous analysis format-was proposed. Commercially available long-period grating hollow core microstructured optical fibers (LPG HCMOF) were used to determine bovine serum albumin (BSA) and albumin from chicken eggs (OVA) in binary mixtures as well as immunoglobulin G (IgG) in the presence of BSA and OVA. LPG HCMOF transmission spectra allowed the detection of both BSA and OVA up to 10 mg/mL with LOD as low as 0.1 and 0.8 µg/mL, respectively. Partial least squares regression (PLS) was utilized for modeling of LPG HCMOF spectral data and quantitative analysis of BSA, OVA, total protein, and IgG in binary and ternary mixtures. Rather high coefficients of determination (R2) and low root mean square error for the calibration (RMSEC) (15%) and prediction (RMSEP) (20%) were obtained for all PLS models. The proposed approach was tested in the analysis of BSA in spiked horse blood hemolyzed (HBH). The results demonstrated the functionality of the proposed approach and offered the opportunity for the creation of a wide range of sensors for protein determination in complex mixtures. Graphical abstract.


Assuntos
Imunoglobulina G/análise , Ovalbumina/análise , Soroalbumina Bovina/análise , Animais , Análise Química do Sangue/métodos , Bovinos , Galinhas , Cavalos , Análise dos Mínimos Quadrados , Camundongos , Modelos Moleculares , Fibras Ópticas
5.
Materials (Basel) ; 11(5)2018 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-29734729

RESUMO

A sensor based on microstructured waveguides (MWGs) with a hollow core inner surface covered with polyelectrolyte-layer-stabilized gold nanostars was developed for the SERS sensing of dissolved analytes. A polyelectrolyte-layer coating over the inner surface of glass cladding served as a spacer, reducing nonlinear optical effects in the glass near plasmonic hotspots of nanoparticles, as a stabilizing agent for thermodynamically unstable gold nanostars and as an optical coating for the fine-tuning of MWG bandgaps. This approach can be used to construct different kinds of SERS sensors for dissolved analytes, providing conservation, the prevention of coagulation, and the drying of a liquid sample for the time required to record the signal.

6.
Anal Chim Acta ; 1019: 14-24, 2018 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-29625680

RESUMO

This review covers the current state of the art of luminescent biosensors based on various types of microstructured optical fiber. The unique optical and structural properties of this type of optical fiber make them one of the most promising integrated platforms for bioassays. The individual sections of this review are devoted to a) classification of microstructured optical fibers, b) microstructured optical fiber materials, c) aspects of biosensing based on the biomolecules incorporated into the microstructured optical fibers, and d) development of models for prediction of the efficiency of luminescent signal processing. The authors' views on current trends and limitations of microstructured optical fibers for biosensing as well as the most promising areas and technologies for application in analytical practice are presented.


Assuntos
Técnicas Biossensoriais , Luminescência , Fibras Ópticas , Estrutura Molecular
7.
J Biomed Opt ; 20(4): 040503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25867617

RESUMO

We introduce a sensitive method that allows one to distinguish positive and negative agglutination reactions used for blood typing and determination of Rh affinity with a high precision. The method is based on the unique properties of photonic crystal waveguides, i.e., microstructured waveguides (MSWs). The transmission spectrum of an MSW smart cuvette filled by a specific or nonspecific agglutinating serum depends on the scattering, refractive, and absorptive properties of the blood probe. This concept was proven in the course of a laboratory clinical study. The obtained ratio of the spectral-based discrimination parameter for positive and negative reactions (I+/I-) was found to be 16 for standard analysis and around 2 for used sera with a weak activity.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/instrumentação , Refratometria/instrumentação , Análise Espectral/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...